Thank you for your clinical feedback on the Mjolnir PRO / TRIO. As a valued existing customer, enjoy an exclusive discount on the Arnnitro platform.
Contact your sales representative or email info@leaflefitech.com to claim.
LEAFLIFE LATEST GAS AROUSED COLD PLASMA PLATFORM
An advanced argon-based cold plasma platform delivering high-density, stable cold plasma with no harmful by-products — safe, effective solutions for skin rejuvenation, anti-aging, inflammation reduction and scalp care.
Plasma is the fourth fundamental state of matter — an ionized gas composed of positively charged ions and negatively charged electrons, created when gases under extreme temperatures or strong electromagnetic fields cause electrons to break free from their atomic nuclei. It is characterized by high temperature, high conductivity and high activity.
Thermal plasma is a gas-like state composed of ionized atoms. When the gas has enough energy, electrons escape from the atom and ionize it with a positive charge. When electrons are "re-captured" by a positively charged atom, energy is released by vibration and rotation of gas molecules, transferring heat to the skin surface.
Under a controllable way, the needle-shaped plasma column is released to the skin surface by the fractional way, dot by dot.
The principle is to ionize gas in the air to create more small electrical arches; tissues are treated by "sublimate" and unwanted heat spreading to surrounding areas is avoided.
Heat widens at the surface and is transferred into the epidermis, all the way down to the papillary layer which contains fibroblast cells — stimulating collagen and tightening the skin.
The result is contraction and tightening of skin cells, leading to skin remodeling and improvement in various signs of aging and scars.
Argon Cold Atmospheric Plasma (CAP) is widely applied in biomedicine and medical aesthetics. Its core advantage is the perfect balance between "highly efficient biological effects" and "extremely low thermal damage". Unlike destructive thermal plasma, cold plasma exhibits a very high electron temperature while heavy particles (ions and atoms) stay near room temperature (typically 35°C–45°C) — acting through synergistic physical, chemical and biological processes.
High-energy electrons bombard argon gas and interact with moisture and oxygen in the air, generating reactive oxygen species (·OH, O₂⁻, H₂O₂) and reactive nitrogen species (NO, ONOO⁻) — the most fundamental biological mechanism of cold plasma.
A weak local electric field creates temporary, reversible nanoscale pores (electroporation) in cell membranes — dramatically enhancing absorption of skincare active ingredients without damage.
Potent bactericidal effects against bacteria, fungi and even drug-resistant strains such as MRSA, through lipid peroxidation, protein oxidation and membrane destruction — plus physical sterilization via electric field and UV radiation.
Higher ionization efficiency and stability; higher plasma density. Monatomic noble gas — not involved in chemical reactions, more stable plasma state.
No-painful, safe, comfortable. Single-atom structure gives more uniform energy distribution; lower electron temperature at the same power.
Controllable running cost with high efficiency; no toxic by-products, in line with green operation requirements.
No oxidising by-products (e.g. ozone, free radicals) — a comfortable treatment environment.
Interference from reactive components (oxygen atoms, nitrogen oxides) in air plasma is avoided.
Conventional fractional RF energy only reaches the epidermis — it can't treat wrinkles and scar problems in the dermis. Mjolnir's needles don't contact skin to operate: no influence by skin elasticity, higher voltage, faster discharge, releasing energy in shorter time with lower skin damage.
Mjolnir Trio's investment cost is much more economical, and it can cover all applications of laser. Safety risk to operator and patient is much lower, with wider usability and no medical limits.
Micro-needle RF excites current at lower frequency; the needle stays in skin for longer time. A single plasma treatment needs less time, and the handle and energy are easier to control — more consistent dots, less damage risk.
Compared with purely invasive treatment methods, Mjolnir is much less dangerous and has much lower consumable cost.
Mjolnir Arnitro: exceptionally high "gas purity" for controlled biochemical effects · excellent "organizational cooling and thermal control" · lower discharge voltage with higher ionization efficiency — a truly next-generation cold plasma platform.
The purple tip modulates just-contact skin; short plasma arcs penetrate dermis cells, sublimating epidermis. Focus adjustable energy level 1–10 for wrinkles, eyes and scar. The sparkles can also break dots, renewing skin mildly. Single needle tip reaches the face's small area — especially eyelid lifting; moles, warts and polyps can be cut fast.
High power design with more energy level choices; stable and precise plasma column. Small dot size and even dots distribution: low pain, no side-burns, no open wounds, gentle treatment feeling, no anesthesia needed, high safety and no downtime. Deep treatment depth, excellent effect.
Dot, line and fractional array are optional — meet target shape precisely. Dots number: 1, 3, 5, 9, 13, 21, 25.
Dot-by-dot scanning operation, short treatment time, good consistency — ensuring excellent effect.
Thin single-dot handle, more ergonomic, easier to hold during operation; more convenient for small skin area precise treatment. High reliability and stable performance.
Low investment but extremely high return.
Sterilization in superficial layers of skin and mucous membranes, with a 40% bacteria reduction in 3 min in medical research.
Skin cleaning for acne with inflammation, allergic dermatitis and eczema treatment.
Increased absorption of vital skincare ingredients, refined pores and overall texture, visible anti-aging results and wrinkles improvement.
Plasma can penetrate into the layer faster and deeper without damaging the skin, penetrating the skin layer with molecules that are more than six times the size of molecules normally able to pass through — enhancing macromolecule penetration of micronutrients.
Exogenous nitric oxide (eNO) induced by plasma plays a key role in angiogenesis, increasing VEGF (fibroblast growth factor-2) and vascular endothelial growth factor proteins. Plasma applied to the epidermis for 24 hours increased blood vessel growth by 40% and hair thickness by more than 30%.
Plasma induces keratinocyte proliferation. Wnt protein and β-catenin play an important role in keratinocytes' multiplication — building blocks of hair, keeping it strong and playing an important role in follicle growth and differentiation.
Plasma acts on the scalp and forms tiny damages on the scalp. Its mechanical and thermal effects promote fibroblast growth factor-2 (FGF-2) and vascular endothelial growth factor, which can increase hair thickness and density, and reduce scalp damage.
Ozone generated by plasma inactivates bacteria, fungi, viruses and biofilms; growth factors targeting cells of the hair follicle are activated, and inflammatory processes are well controlled.
Chinese Patent Database registered — Utility Model, Patent No. 201820333811.0, authorized 2021-03-08.
CTI Core Test Instrument Dashboard verified — every unit ships with full quality traceability.
CE Medical and Safety Compliance
Thai FDA Official Registration
KF Registration
Health Canada Class 3 Registration
Anvisa Official Registration
FDA Class II Official Certification